Placement Environment Requirements for Ice maker
Placement Environment Requirements Commercial Ice Machine Placement Environment Requirements: I. Space Requirements The commercial ice machine should be placed in a well-ventilated area. This helps the ice machine dissipate heat, preventing ...
Why the Display Shows Water Shortage Protection
Display Shows Water Shortage Protection Causes and Solutions: 1.Check if the water inlet valve is open and if the water pressure is sufficient and continuous. 2.Check if the ice-making drain is continuously draining water. If so, clean the drain ...
Why Normal Display and Water Flow but No Ice Production
Normal Display and Water Flow but No Ice Production Solutions: 1.If the machine lacks sufficient ventilation space, turn it off and check if the display temperature exceeds 40°C. If it does, pull out the machine, allow it to cool, and restart. 2.If ...
Why the"Ice Full" Display on Startup
"Ice Full" Display on Startup Causes and Solutions: 1.If the ice full switch is not properly secured, reattach it. 2.If the ice diverter panel has fallen or is incorrectly installed, adjust and reinstall it. 3.If both the ice full switch and ice ...
Why the Frost Formation on the Ice Tray or Irregular Ice Formation
Solution: Clean the water pump and spray pipes.